Graco’s two- and three-component proportioners offer precise and reliable electronic plural component proportioners for a broad range of solventborne, waterborne, and acid catalyzed materials. From entry level to upgraded applications, the ProMix 2KS and 3KS systems provide flexibility and increased efficiency.

  • Offers the highest degree of ratio assurance
  • Provides critical process variable feedback
  • Built in system safeguards
  • Effective color change solution
  • Efficient material tracking and reporting
  • Manual and automatic configurations
  • Intrinsically safe fluid panels easily integrate into hazardous areas
  • Single- or multi-color and catalysts
  • Accurate ratio assurance for superior finish quality
  • Simple programming allows fast set up and efficient process control
  • Advanced web interface provides consolidated system management and reporting

ProMix 2KS Manual System

Maximum working air pressure

100 psi

Air supply

75–100 psi

Air filter inlet size

3/8 npt(f)

Air filtration for air logic and purge air (Graco-supplied)

5 micron (minimum) filtration required; clean and dry air

Air filtration for atomizing air (user-supplied)

30 micron (minimum) filtration required; clean and dry air

Mixing ratio range

0.1:1–50:1

Fluids handled

one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates

Viscosity range of fluid

20–5000 cps

Fluid filtration (user-supplied)

100 mesh minimum

External power supply requirements

85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge

Operating temperature range

41–122°F

Environmental conditions rating

indoor use, pollution degree (2), installation category II

Wetted parts

303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE

Maximum fluid working pressure

Base system

4000 psi

Low pressure color change

300 psi

High pressure color change

3000 psi

Coriolis Meter

2300 psi

Fluid Flow Rate Range

G3000, G250 Meter

0.02–1.00 gpm

G3000HR, G250HR Meter

0.01–0.50 gpm

Coriolis Meter

0.005–1.00 gpm

S3000 Solvent Meter (accessory)

0.01–0.50 gpm

Fluid Porting

Flow Meter Fluid Inlet

1/4 npt(f)

Dose Valve/Color Valve Adapter Inlets

1/4 npt(f)

Fluid Outlet Size (static mixer)

1/4 npt(f)

Noise Level

Sound pressure level

below 70 dBA

Sound power level

below 85 dBA

ProMix 2KS Automatic System

Maximum working air pressure

100 psi

Air supply

75–100 psi

Air filter inlet size

3/8 npt(f)

Air filtration for air logic and purge air (Graco-supplied)

5 micron (minimum) filtration required; clean and dry air

Air filtration for atomizing air (user-supplied)

30 micron (minimum) filtration required; clean and dry air

Mixing ratio range

0.1:1–50:1

On-ratio accuracy

up to +/- 1%, user selectable

Fluids handled

one or two component: solvent and waterborne paints, polyurethanes, epoxies, acid catalyzed varnishes, moisture sensitive isocyanates

Viscosity range of fluid

20–5000 cps

Fluid filtration (user-supplied)

100 mesh minimum

External power supply requirements

85–250 Vac, 50/60 Hz, 2 amps maximum draw, 15 amp maximum circuit breaker required, 8 to 14 AWG power supply wire gauge

Operating temperature range

41–122°F

Environmental conditions rating

indoor use, pollution degree (2), installation category II

Wetted parts

303 and 304 stainless steel, Tungsten carbide (with nickel binder), perfluoroelastomer, PTFE

Maximum fluid working pressure

Base system

4000 psi

Low pressure color change

300 psi

Coriolis Meter

2300 psi

RoboMix system

190 psi

Flow control

190 psi

Fluid Flow Rate Range

G3000, G250 Meter

0.02–1.00 gpm

G3000HR, G250HR Meter

0.01–0.50 gpm

Coriolis Meter

0.005–1.00 gpm

S3000 Solvent Meter (accessory)

0.01–0.50 gpm

Fluid Porting

Flow Meter Fluid Inlet

1/4 npt(f)

Dose Valve/Color Valve Adapter Inlets

1/4 npt(f)

Fluid Outlet Size (static mixer)

1/4 npt(f)

Noise Level

Sound pressure level

below 70 dBA

Sound power level

below 85 dBA

Product Downloads

312775G – ProMix 2KS, Installation Manual for Manual Systems, English

312776F, ProMix 2KS Manual Systems, Operation Manual, English

312777E – ProMix 2KS Plural Component Proportioner, Repair-Parts Manual, English

312778D – ProMix 2KS, Installation Manual for Automatic Systems, English

312779F, ProMix 2KS Automatic Systems, Operation Manual, English

312781E, Fluid Mix Manifold Instruction-Parts Manual, English

312784E, Gun Flush Box Kit, Instruction-Parts, English

312786G – Dump Valve and Third Flush Valve Kits Instructions-Parts Manual, English

312787G, Color Change Module Kits Instructions-Parts Manual, English

406719B, 15T632 Air Flow Switch Kit, Instructions, English

406715B 15U955 Injection Kit for ProMix® 2KS Proportioners using Dynamic Dosing, English

406799A, 15V256 Automatic Upgrade Kit, Instructions/Parts, English

406804B, Instruction Form for Integrator Kit 24B618 (100cc) English

406713B, Dispense Valve Acid Kit, Instructions-Parts, English

406800B, 15V825 Discrete I/O Board Kit, Instructions/Parts, English

312782D – Air Actuated Dispense Valve Instruction-Parts Manual, English

312783E – Color and Catalyst Change Valves Instruction Manual, English

312785C, Gateway Network Communication Kits Instruction-Parts Manual, English

313290A – 15V950 Floor Stand, English

313212A, 15V534 Gun Flush Box Interface Kit Instruction-Parts Manual, English

313542E – 15W034 Beacon Kit and 122193 Beacon Tower, Instruction-Parts Manual, English

339996EN ProMix 2KS and 3KS Brochure

344807EN-A ProMix 3KS Flyer

 

344880EN ProControl 1KS Flyer

2KS Waterborne Urethane

3KS CARC Application

Viscosity Control with ProMix 3KS