Lincoln Industrial QLS / SL Injectors

System description:

The QSL metering devices are designed for high pressure up to 300 bar, as they only have a metal-to-metal fit. Each individual metering device can be set from 0.05 to 0.4 cm3 / stroke. The function is generally visually monitored. On request, electrical monitoring and even a GSM controlled system is possible.

  • QSL-Injectors for grease
  • For Single-line lubrication systems 603 S / 653 S and Centro-Matic
  • Maximum operating pressure 300 bar
  • Type – Dosage
    QSL 0.05: 0.05 cm3
    QSL 0.1: 0.1 cm3
    QSL 0.2: 0.2 cm3
    QSL 0.3: 0.3 cm3
    QSL 0.4: 0.4 cm3

 

  • SL-Injectors for grease
  • For Single-line lubrication systems 603 S / 653 S and Centro-Matic
  • Maximum operating pressure 240 bar
  • With visual function indicator. Single injectors or with manifold banks available – except SL-11 injectors
  • Type – Dosage
    SL-33: 0.016 – 0.049 cm3
    SL-32: 0.016 – 0.131 cm3
    SL-1: 0.131 – 1.31 cm3
    SL-11: 0.82 – 8.19 cm3
    Injectors Type SL-33, SL-32 and SL-1 also available in stainless steel

 

  • SL-Injectors for oil
  • For Centro-Matic Single-line lubrication systems
  • Maximum operating pressure 68 bar
  • With visual function indicator. Single injectors or with manifold banks available
  • Type – Dosage
    SL-42: 0.016 – 0.049 cm3
    SL-43: 0.016 – 0.131 cm3
    SL-41, SL-44: 0.131 – 1.31 cm3
    (SL-41 has no indicator pin)